48
Defective Relay
ICE / FROST ON EVAPORATOR
Ice / frost on evaporator.
Condensate drain
plugged.
Clear drain.
Air leak.
Check product door
seal and cable
openings in cabinet.
CONDENSATE ON OUTSIDE OF PRODUCT DOOR
Condensate on outside of
product door.
Machine in direct
sunlight.
Move machine.
Machine in location with
humidity above 70%.
Move machine.
COMPRESSOR WILL NOT STOP
Compressor will not stop.
Defective thermostat. Replace.