AXIS M5013 PTZ Dome Network Camera
Events
Events
Predefined parameters, known as an Event or Even t Type, can trigger actions in the Axis product. A common event type is an alarm
that causes the product to upload images to an Event S erver.
Triggered events - are activated by a signal, for example motion detection.
Scheduled events - run at preset times, in a r epe ating pattern on selected weekdays.
Actions - refer to what happens when an event occurs.
Triggered events can be activated by:
• Motion detection, see
page 24
• Audio detection, see
page 26
• A trigger from an uploaded application, see
Applications, on page 21
• Pan Tilt Zoom — when t he view stops at a preset position
• System events, for example on boot.
Event actio ns include:
• Uploading images to an event server or send images by email
• Sending notification me ss ages and emails
• Pan Tilt Z oom — go to a preset
Event Servers
Event servers receive uploaded image files and/o r not
ification messages. To s et up event server connections in the Axis p roduct, go
to Events > Event Servers and e nter the required information for the server type.
Note
Email servers are configured under System Options > Network > SMTP (email).
When the setup is complete, click Test to test the connection (the connection test takes approximately 10 seconds).
Server type
Purpose
Information required
FTP Server
• Receives uploaded images • Descriptive name
• Network address and upload path
• User name and password
HTTP Server
•Receivesnotifi cation messages
• Receives uploaded images
• Descriptive name
• URL (IP address or host name)
•Us
er name and password
• Proxy settings
TCP Server
•Receivesnotifi cation messages • Descriptive name
• Network address (IP address or host name)
• Port number
For details on each settings, see the online help .