Axis Print Server 5470e User Manual Page 173

  • Download
  • Add to my manuals
  • Print
  • Page
    / 267
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 172
AXIS 5470e User’s Manual Section 13: Using Logical Printers
173
String Substitutions The string substitution function performs search and replace
operations on the print data. The primary application is to replace
printer control commands. Up to twenty string substitutions may be
specified individually for each logical printer.
All strings must be entered as hexadecimal byte values, and each
match and substitute string must be preceded by a count byte.
You substitute command strings by editing the String Substitutions
(PRx_STR) parameter.
Example: Assume that you want to replace the UNIX New Line (hex
0A) with an
ASCII NewLine (hex
0D 0A) for logical printer PR1.
Follow the instructions below to substitute command strings:
1. Click admin and the Logical Printer Settings button.
2. Select the PR1 tab.
3. Enter the string 01 0A 02 0D 0A in the String Substitutions
text field.
4. Click OK.
This is the default setting for logical printers PR5 through PR8.
Hex Code Explanation
01 length of the string you want to replace
0A the string you want to replace
02 length of the substitute string
0D 0A the substitute string
Page view 172