Axis Print Server 5470e User Manual Page 248

  • Download
  • Add to my manuals
  • Print
  • Page
    / 267
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 247
Section 24: Test Button AXIS 5470e User’s Manual
248
Section 24 Test Button
The test button is located on the front right hand side of the AXIS
5470e and is used for:
Printing a test page, checking the connection to the printer.
Printing a parameter list, showing the AXIS 5470e current set-
tings.
Resetting the AXIS 5470e parameters to the factory default set-
tings.
The Test Page Press the test button once to print a test page. If the test page prints,
the parallel interface is functioning correctly. The printed Test Page
contains basic information about the AXIS 5470e. It is recommended
that you print a test page every time you have connected the AXIS
5470e to a printer.
The Parameter List Press the test button twice to print a parameter list showing the
current AXIS 5470e settings. This list provides comprehensive details
of all the parameters and their current status. Refer to The Parameter
List, on page 231.
If you want to change any of the parameters, use one of the methods
that are described in Management and Configuration, on page 134.
Factory Default
Settings
Follow the instructions below to reset the AXIS 5470e to the factory
default settings:
1. Remove the external power supply to switch off the AXIS 5470e.
2. Press and hold down the test button, while you plug the external
power supply back in. Continue to hold down the test button,
until the network indicator begins to flash at one second
intervals. This should take at least 5 seconds.
3. Release the test button and wait until the network indicator
flashes at least five times.
Page view 247
1 2 ... 243 244 245 246 247 248 249 250 251 252 253 ... 266 267

Comments to this Manuals

No comments