Page view 62
AXISA1001NetworkDoorController&AXISEntryManager
TechnicalSpecifications
Relay
2–3
Forconnectingrelaydevices.Usethehardwarepin
chart.SeeConguretheHardwareonpage15.
Thetworelaypinsaregalvanicallyseparatedfromthe
restofthecircuitry.
Maxcurrent=700mA
Maxvoltage=+30VDC
12VDC
5
Forpoweringauxiliaryequipment.
Note:Thispincanonlybeusedaspowerout.
Maxvoltage=+12VDC
Maxload=500mA
24VDC
6
Notused
Important
TheoutputcircuitsinthissectionareClass2powerlimited.
TamperingAlarmPinHeader
Two2-pinheadersforbypassing:
Backtamperingalarm(TB)
Fronttamperingalarm(TF)
FunctionPinNotes
Backtamperingalarm
1–2
Fronttamperingalarm
1–2
Tobypassthefrontandbacktamperingalarmsimultaneously,connectjumpers
betweenTB1,TB2andTF1,TF2respectively.Bypassingthetamperingalarms
meansthatthesystemwillnotidentifyanytamperingattempts.
Note
Boththefrontandbacktamperingalarmsareconnectedbydefault.Thecasingopentriggercanbeconguredtoperforman
actionifthedoorcontrollerisopenedorifthedoorcontrollerisremovedfromthewallorceiling.Forinformationabouthow
tocongurealarmsandevents,seeAlarmandEventConguration.
ConnectionDiagrams
Connectdevicesaccordingtothehardwarepinchartgeneratedthroughthehardwareconguration.Formoreinformationabout
hardwarecongurationandthehardwarepinchart,seeConguretheHardwareonpage15.