Greasing Procedures
Advanced Dicing Technologies Ltd.
3.4-4
b. From the Setup & Diagnostics tree, select saw > Dicer >
Axes > X.
c. In the lower right pane, click Init to initialize the axis, then click
Toggle Self Test. The X Axis begins moving automatically
between its two limits. Allow the X Axis to continue moving for
one minute, then click Toggle Self Test again to turn off the
self-test.
3.4.2.1 Removing the Old Grease from the X Axis
On a quarterly basis, the old grease should be removed from X Axis before
applying new grease.
To Remove Old Grease from the X Axis:
1 Open the Front Door of the System to reveal the X Axis Leadscrew.
2 Remove the old grease from the Leadscrew using waste paper.
3 Grease the X Axis, as described in section 3.4.2.
3.4.3 Greasing the Y and Z Axes
Grease the Y and Z Axes simultaneously, by performing the following
procedure.
To Grease the Y and Z Axes:
1 Remove the Maintenance Panel.
1 X Axis Grease
Nipple
2 Leadscrew
Figure 3-4: Left X Leadscrew and Grease Nipple
2
1
Note: On a quarterly basis, remove the old grease before applying the new
grease, as described in section 3.4.2.