AXIS 292 - Alarms
Notes: •The URL for an HTTP event server should be set to: http://<IP address>/axis-cgi/admin/alarm.cgi
•The TCP alarm port on the AXIS 292 is configured on the Network Settings page.
3. Configure the Event Type to send a notification message to the event server (i.e. the AXIS 292).
Notification syntax
The notification message is formatted differently for TCP and HTTP.
TCP notification syntax
Enter the notificat
ion message in the Message field, in the format:
The message is sent to the TCP port (default
2048) on the AXIS 292.
HTTP notification syntax
Enter the notificat
ion message in the Custom parameters field, in the format:
The message is sent to the HTTP port (default
80) on the AXIS 292.
Note:
All non-alphanumerical characters included in an HTTP notification message must be URL-encoded.
For example, a blank space must be written as %20, as in Door%20is%20open.
For more information, please see the online help. For more information concerning the video encoder, see
that product’s documentation and online help.
sourcename=<name from list>&textmessage=<my message>
For example: sourcename=DoorCam1&textmessage=Door is open
sourcename=<name from list>&textmessage=<my message>
For example: sourcename=DoorCam1&textmessage=Door%20