AXIS Q19 Series - Live View Config
Output Buttons
The output buttons are used to manually activate and inactivate devices connected to the output ports, for example to switch
a light on and off. To display output buttons on the Live View page, select the type of control to use for the port from the
drop-down list:
Pulse - Activates the output for a defined period of time
Active/Inactive - Displays two buttons, on for each action (on/off)
The camera’s I/O ports can be configured as input or output under System Options > Ports & Devices > I/O Ports. See I/O
Ports, on page 46.