VI Appendix
VI.1 Delivery package, transport, storage, maintenance, disposal
Delivery — 1 digifas™ 7100 series servo amplifier
package : — 3.5" diskette with the operator software BS7200
— 2 ring cores
— installation/commissioning manual for digifas™ 7100
— BS7200 operating manual
— installation/commissioning manual for the CONNECT module,
if one is built in
Transport : — only by qualified personnel
— only in the original recyclable manufacturer’s packaging
— avoid shocks
— the servo amplifiers contain electrostatically-sensitive components,
which can be damaged by incorrect handling.
Discharge yourself before you touch the servo-amplifier.
Avoid touching highly insulating materials (artificial fabrics,
plastic wrappings etc.). Place the servo amplifier on a conductive base.
— if the packaging is damaged, check the unit for visible damage. In such
a case inform the shipper and the manufacturer.
Storage : — only in the original recyclable manufacturer’s packaging
— the servo amplifiers contain electrostatically-sensitive components,
which can be damaged by incorrect handling.
Discharge yourself before you touch the servo-amplifier.
Avoid touching highly insulating materials (artificial fabrics,
plastic wrappings etc.). Place the servo amplifier on a conductive base.
— max. stacking height digifas™ 7103...7116 : 10 cartons
digifas™ 7133...7150 : 5 cartons
— storage temperature –25 ... +85°C, max. 20°/hr variation
— humidity relative humidity max. 95% no condensation
— storage duration < 1 year without restriction
> 1 year : the capacitors must be re-formed before
commissioning the servo amplifier.
To do this: remove all electrical connections,
feed the servo amplifer for about 30 min
from single-phase 230V AC on terminals L1 / L2.
Maintenance : — no maintenance required
— opening the equipment housing invalidates the guarantee
Cleaning : — if the housing is dirty : clean with isopropanol or similar
do not immerse or spray
— if there is dirt inside the unit : to be cleaned by the manufacturer
— if the fan screen is dirty : clean with a dry brush
Disposal : — the servo amplfier may be reduced to its principal components by
undoing all screw connections (aluminium heat sink and front panel,
steel housing sections, electronics boards)
— the disposal should be performed by a certified disposal company.
We can give you suitable addresses.