ADT Model 7100 Semi-Automatic Dicing System Operations Manual
Kerf Checking
P/N 97100-9002-000-14 Ver 06/05
6.3-11
Figure 6-31 below illustrates a user choosing a Reference Position: Lower
Edge Model and Pattern Type: Kerf up during the Kerf Teach process.
Other parameters relating to Kerf Checks are either optional or are
automatically specified by the Teach procedure.
For more information about Kerf Check parameters, see Appendix 3.
To Teach the Kerf Check:
1 Click Run . The System starts dicing the Workpiece
automatically, according to the parameters defined in the Recipe.
2 After two or three cuts, select Auto Stop from the Auto menu or
click .
3 In the Programming Workspace, click Teach Kerf. The Video
Workspace is displayed with a blue Teach Area in the Field of View
(FOV). The Camera moves over the Cut Position defined during
Alignment (see
section 6.1.1.2).
4 Click Next. The Camera moves to the first check point.
5 Set the focus, zoom and illumination using the Z/T Axis, Zoom and
Illumination Controls respectively, so that the image is clear. It is
recommended to set illumination so that outside information on the
edge of the Kerf is eliminated as much as possible. Ideally, the Kerf
should appear as dark and the outside area as white/light as possible.
Refer to
section 2.2.10.2 for more information about setting these
features.
6 Move to the Kerf center: using the Display Controls, position the Teach
Window so that it fully surrounds a section of Kerf in the Y direction,
Figure 6-31: Pattern: “Kerf Up” with Reference Position: “Lower Edge”