Page view 349
Initializing the System
Advanced Dicing Technologies Ltd.
10.3-2
3 From the Setup & Diagnostics tree, select Saw > Dicer to display the
following:
4 Click Init Z initialize the Z-Axis.
5 Initialize the X, Y and T (Theta) axes by clicking the buttons provided.
The X, Y and T axes may be initialized in any order.
6 Click Init Spindle to initialize the Spindle.
7 Click Init Vision to initialize the Vision System
Figure 10-2: Subsystem Initialization Screen
Note: While Dicer components must be initialized in the order described
above, there is no need to wait for one initialization procedure to finish before
performing the next one.