ADT Model 7100 Semi-Automatic Dicing System Operations Manual
Initializing the System
P/N 97100-9002-000-14 Ver 06/05
10.3-1
10.3 Initializing the System
When a problem occurs in the Model 7100, the user can try to solve the
problem by re-initializing the System. This will often solve the problem and
enable normal operation to resume.
Before re-initializing the whole system, it is recommended to first try re-
initializing a specific system component (see
section 10.3.1), then the Dicer,
and only if the problem persists, the whole system.
To Initialize the System:
From the User menu, select System Init.
10.3.1 Initializing Dicer Components
When a problem occurs in a component of the Model 7100, the User can try
to solve the problem by reinitializing that particular component. This will
often solve the problem and enable normal operation to resume.
To Initialize Dicer Components:
1 Remove the Workpiece, if present, from the Cutting Chuck.
2 Click in the toolbar to display the Setup & Diagnostics workbook.
Caution: It is recommended to remove the Workpiece, if present, from the
Cutting Chuck before running the initialization routine.
Note: For systems equipped with an Autoloader, refer to the Autoloader
Manual.
Note: The System can also be initialized by clicking Dicer Init in the Saw
screen of the Setup & Diagnostics workbook, or by right-clicking the Dicer
Status Indicator (see Chapter 2) and selecting (Dicer) Init from the popup
menu displayed.